STAGE MANAGEMENT
An AMX control system is used to coordinate lighting, sound and stage management operations on a series of touch screens. These incorporate a cue light system and remote control of a number of auditorium features including the projection screen, house lights, curtains and backstage working lights.
A Tecpro communications system is fitted with connections points around the Hall and in backstage areas.
A show relay system is provided which includes audio and video from four remote control colour cameras. These may be routed all over the building as required. Backstage calls may be made from a number of control positions around the stage and from stage door.
STAGE / PLATFORM
13m wide
10m deep
The stage is level (i.e. no rake) and consists of oak effect panels which may be removed to provide access to power and AV system connection. A floor plan is available upon request.
A passenger lift rises from Stage Door to stage level. Its safe working load is 1000kg (evenly distributed,) the dimensions are as follows:
Entrance:
1m wide
2m high
Internal:
1.3m wide
1.7m deep
Between 2.2m and 2.3m high - the ceiling is arched.
A goods lift with a safe working load of 500Kg (evenly distributed) is fitted in the stage to allow access to a storage area below. This cannot be used during performances and does not provide direct access to the street. Its dimensions are as follows.
1.7m wide
2.8m deep
2.1m high
A modular choir riser system is provided for up to 54 people. This consists of the following sections:
3 x 2.4m X 1m
6 x 2m X 1m
6 x 1m X 1m
Each section has removable legs which may be selected from the following lengths:
200, 400, 600mm
100 black armless orchestral chairs.
70 music stands with oak desks, these may be fitted with lights if required.
Black / grey Harlequin dance floor.
Oak lectern with microphones and AV equipment fitted.
Steinway model D concert grand piano.
A 63A three phase Ceeform socket is provided USL and USR
Performances with more than 40 people on stage will affect the Halls seating capacity pro rata.
SOUND SYSTEM
The Meyer sound system can be operated in a number of ways. These include “Manual”, where the console drives the system or “Cinema”, where the Lexicon 7.1 Surround Sound Controller drives the system in conjunction with the data projector and AV playback equipment.
The Hall is fitted with a Sennheiser infrared amplification system for the hearing impaired. Headsets are available upon request.
The front of house PA system consists of the following speakers:
· Two flown seven segment M1D line arrays driven in stereo.
· Two UPJ and UPM fills for the balcony.
· Two PSW-2 sub bass cabinets and three UPM front fills fitted in the stage.
· Nine under balcony UPM delays.
· Nine additional UPM’s around the Hall which provide the surround sound effect.
· Six UM-100P powered monitor speakers available upon request.
· Two CQ1 speakers may be added on stage to complement the permanent system.
FRONT OF HOUSE EQUIPMENT
PM1D V2 sound console with 96 input channels (48 patchable channels available on stage). Linked to a dedicated PC running management software.
Tascam DA-45HR DAT Recorder.
Tascam CD-RW2000 CD Recorder.
Tascam MD-801R MkII Minidisk Recorder.
Tascam 122MkII Cassette Recorder.
Denon Twin deck CD player
8X AKG SR4000 radio microphone receivers linked to a PC running management and diagnostic software
Two monitor speakers are installed in the control booth arranged around the sound console.
MICROPHONES
4X Shure SM58.
2X Shure SM58S.
4X Shure SM57.
4X AKG 391.
4X AKG CK91 with pop shields.
2X AKG 747.
1X EVRE20.
1X Beyerdynamic M88 TG.
2X Crown 300AL (fitted to lectern).
8X AKG HT4000 handheld transmitters with C5900WL1 capsules.
4X AKG D880WL1 (alternative microphone capsules for the above).
8X AKG PT4000 belt pack transmitters with DPA lapel microphones.
2X Head worn DPA 5E67DHN microphones.
4X Klark Teknik DN100 active DI boxes.
1X RS Components gooseneck microphone (sound console talkback).
MICROPHONE STANDS
8X Tall boom stands (tripod).
2X Straight pump stands.
4X Small boom stands (tripod).
4X weighted round bases.
2X Small table stands for AKG 747.
STAGE MONITORS
6X Meyer UM-1P powered stage monitor with custom cable looms.
COMMUNICATIONS
10X Tecpro communications belt packs.
10X Tecpro single muff headsets.
2X AKG K271 headphones.
CABLE
6X 8 way multicores.
6X 8 way stage boxes (8 XLR sends).
2X 25m 8 way multicores with XLR tails.
4X 20m XLR cables.
22X 10m XLR.
7X 5m XLR cables.
6X 2m XLR cables.
4X Male to male XLR sex changers.
4X ¼” unbalanced male jack to jack.
4X 316 PO jack to male XLR.
4X 316 PO jack to female XLR.
1X Stereo mini jack to 2X mono ¼” jack.
2X ¼” mono jack to female XLR.
1X ¼” balanced jack to male XLR.
1X ¼” balanced jack to female XLR.
2X Stereo phono to phono cable.
PORTABLE PA
Flight cased rack which can be used in the function rooms. Containing the following equipment:
1X Soundcraft Spirit E12 mixing console.
1X Behringer Ultragraph Pro FBQ3102 graphic equalizer.
1X Nexo PS 8 Amplifier.
2X Nexo PS 8 loudspeakers with stands.
1X EMO power distribution board.
4X 10m Speakon to Speakon cable.
2X 25m Speakon to Speakon cable.
4X 4 pole Speakon couplers.
1X HHB “Burnit” CDR-830 CD recorder.
1X Shure SM58 Radio microphone with boom stand.
ADDITIONAL EQUIPMENT
2X Spare AKG SA60 microphone clips.
1X Spare generic condenser microphone clip.
4X Spare microphone clip inserts.
4X lapel microphone spares kits.
1X Yamaha MS101 Mk.2 powered monitor speaker.
LIGHTING SYSTEM
The lighting system is controllable via the console in the Control Booth and from the AMX touch screens. The house truss can support up to 50 kg per meter span evenly spaced. This truss system is a bespoke design for the Hall. We have some extra fittings to allow additional equipment to be attached to the truss which can be set at any trim height from stage level to the maximum out dead at the ceiling. The standard rig incorporates an array of open white generic lighting to suit orchestras, and moving lights which may be used when required by other shows. The additional equipment available for the truss is as follows.
18X ETC Source Four Zooms
1X ETC 19 degree Source Four Profiles
PLEASE NOTE FOCUSSING CAN ONLY BE ACHIEVED AT THIS TIME BY BOUNCE FOCUS METHOD. PLEASE CONTACT THE TECHNICAL OFFICE FOR CLARIFICATION on 02078247609
Lighting control
Avolites Diamond 4 Elite lighting console.
Fixtures on truss
8X Clay Paky Stage Profile Plus SV.
40X Source four Par CP62.
8x Source four 15-30 profiles
Additional equipment (not for truss use)
6x Clay Paky Stage Profile Plus SV in roof positions.
2x Clay Paky Stage Profile Plus SV for floor use.
2X Robert Juliat Ivanhoe follow spots.
8x par 64 cp62 floorcans in black.
Dimming
48X 10A dimmer channels split evenly between USL and USR available on Socapex outputs and 16A (6x16A 18 x Soca per side)
10X 10 dimmer channels split between the stage left and stage right bars above the Gallery.
4X 10A dimmer channels in the arch at the back of the Hall.
3X 10A dimmer channels on the front of the control box.
Misc.
“B” size gobo holders for the Source Fours
15A TRS cabling and grelcos
16A TRS cabling and adaptors
Various other power adaptors e.g. 13A to 15A etc.
We hold a basic range of gel and can source more if you require it.
VIDEO EQUIPMENT
The Hall is fitted with a front projection screen which can be rolled in and out via the AMX system. Two automated black legs my also be rolled in to convert the screen to 4:3 aspect ratio. The throw from the installed data projector to the screen is approximately 30m.
The 7kW Roadster data projector is fed via a comprehensive video network that allows any of the PC’s or media players to be displayed on the screen. Please be aware the projector makes a certain level of noise in the auditorium when in use. May not be suitable for quiet performances.
PC’s and visual media players can also have their outputs fed from the stage or a number of other locations around the building into the data projector or the flat screen monitors in many of the rooms front or back of house.
FRONT OF HOUSE EQUIPMENT
Professional DVD player and VHS recorder
HALL CAPACITY
Stalls: 561
Gallery: 344
TOTAL: 905
The Halls capacity is a total of 970 persons within the Building at any one time comprising an aggregate of a maximum of 900 members of the public and 70 staff (both of Cadogan and the Hirer) and performers.
From the above seating areas Cadogan Hall removes:
10 seats from the Stalls (4 in row M and N, 2 in row L) held for Cadogan Hall
12 seats from the Stalls (Row T) as last sell, sightline seats
28 seats from the Gallery in Blocks A & P as last sell sight line seats
Given the above holds, the maximum number seats available for sale is 855
DRESSING ROOMS
Dressing Room 1: 4-5 people with en-suite facilities
Dressing Room 2: 4-5 people with en-suite facilities
Dressing Room 3: 4-5 people with en-suite facilities and disabled access
Dressing Room 4: Ensemble room. Can accommodate 40-50 people
Dressing Room 5 Ensemble room. Can accommodate 40-50 people
Dressing Room / Production Office – Can accommodate 3 people
Backstage calls to all back stage areas.
Show relays to Dressing rooms 1, 2 and Green Room
Dressing rooms 1, 2, 3 & 6 have chargeable telephones
Payphone located within Green Room
Male and Female toilets and showers are on Lower Ground level
Bars:
Caversham Bar: Main foyer space
Gallery Bar: Within main auditorium to the rear of central gallery seating
Box Office:
Patron Edge ticketing solution
Patron Edge Online ticketing solution
Patron Edge Ticket Collection solution
Inbound call monitoring
RF hearing loop at box office counter
|